PE Insulated Air Core/Jelly Filled Star Quad Railway Signalling Cables to VDE 0816/DIN 57816

 
Applications
 
  The cables are designed to give good protection to the core against inductive interference. The cables are used for outdoor signaling equipment.
Standards
  • VDE 0816/DIN 57816
Construction  
 
Conductors: Solid annealed bare copper 0.9/1.4mm as per ASTM B-3/IEC 60228 Class 1.
Insulation: Solid polyethylene as per ASTM D 1248/IEC 60708.
Cabling Element: Four insulated conductors are twisted together to form a quad.
Cable Core Assembly: The cores are cabled together in concentric layers to form the cable core. Units are identified by colour coded binders.
Core Wrapping: One or more non-hygroscopic polyester tapes are helically or longitudinally laid with an overlap.
Electrostatic Screen: Copper tape or copper wire braid with wire diameter of 0.12mm.
Bedding: PE or LSZH.
Electrostatic Armour: Two steel tapes of 0.5mm or 0.8mm are helically applied with gap. The outer tape will cover the gap left by the inner one.
Sheath: PE, PVC or LSZH.
Ripcord: Nylon ripcord may be placed parallel to the cores to facilitate sheath removal.
Electrical properties  
 
Nominal Conductor Diameter mm 0.9 1.4
Conductor Size mm2 0.636 1.539
Maximum Conductor Resistance @20°C Ω/km 28 12.1
Minimum Insulation Resistance @500V DC MΩ.km 35000 5000
Maximum Resistance Unbalance % 2.5 2.5
Maximum Mutual Capacitance @0.8KHz nF/km 45 50
Maximum Capacitance Unbalance @1KHz pair-to-pair pF/500m 250 250
Maximum Capacitance Unbalance @1KHz pair-to-ground pF/500m 1200 1200
Maximum Average Attenuation @1KHz dB/km 0.7 0.46
Maximum Average Attenuation @10KHz dB/km 1.6 0.85
Maximum Average Attenuation @30KHz dB/km 2.1
1.3
Dielectric Strength Conductor to Conductor 3secs V DC 3000 3000
Conductor to Screen 3secs V DC 3500 3500
Nominal Insulation Thickness mm 0.45 0.65
Nominal Insulated Conductor Diameter mm 1.8 2.7
Reduction Factor
Type group Frequency Hz Cable reduction factor(planning values)at field strength
70V/km 100V/km 350V/km
1,5
16 2
3
0.70 0.60 0.92
2,3,6,7 0.55 0.45 0.80
4,8 0.30 0.25 0.70
1,5 50 0.45 0.38 0.52
2,6 0.21 0.17 0.29
3,7 0.42 0.37 0.30
4,8 0.17 0.14 0.12
Reference length is 300m. Conversion factor for different lengths L (at least 200m): L/300
Type Codes
AJ Outdoor cable with protection against inductive influences
2Y Solid PE
Y PVC
H LSZH
(St) Static shield of plastic-backed aluminum Tape for indoor cables
D Shield of copper wire whipping.
S Railway signaling cable
Lg Stranded in layers
(…Cu) Total cross section of copper shield in mm sq
(fK) Longitdinally applied copper tape, supplement to (St)
2B… two layers of steel tape, thickness of steel tape in mm
Mechanical and thermal properties
  Temperature range during operation (fixed state) : -30°C – +70°C
  Temperature range during installation (mobile state) : -20°C – +50°C
  Minimum bending radius : 15 x Overall Diameter.
Colour Code
 

Coloured rings on the insulation.

The tracer quad in each layer has a red helix.

 
Dimensions and weight
  VDE CODE:
  Copper tape screen & steel tape thickness of 0.5/0.8mm
  AJ-2Y(St)YbY…x4x0.9/1.4 S Lg (fK) (2B 0.5)     AJ-2Y(St)YbY…x4x0.9/1.4 S Lg (fK) (2B 0.8)
  Copper wire screen (wire diameter of 1.2mm) & steel tape thickness of 0.8mm
  AJ-2YDYbY…x4x0.9/1.4 S Lg (…Cu/2B 0.5)     AJ-2YDYbY…x4x0.9/1.4 S Lg (…Cu/2B 0.8)
 
Cable Code Number of
Quads
Nominal Bedding/
Sheath Thickness
mm
Nominal Overall
Diameter
mm
Nominal Weight
kg/km
Type 1: 0.9mm Conductor, 1.8mm Insulated Wire, Copper Tape Screened, RF 0.6 Steel tape thickness 0.5mm
TP816AJ-2Y(St)YbY-S Lg (fK)(2B0.5)-3Q09 3 1.7/1.8 22.0 810
TP816AJ-2Y(St)YbY-S Lg (fK)(2B0.5)-5Q09 5 1.7/1.8 25.5 1035
TP816AJ-2Y(St)YbY-S Lg (fK)(2B0.5)-7Q09 7 1.7/1.8 26.5 1150
TP816AJ-2Y(St)YbY-S Lg (fK)(2B0.5)-10Q09 10 1.8/2.0 32.5 1550
TP816AJ-2Y(St)YbY-S Lg (fK)(2B0.5)-14Q09 14 1.8/2.0 35.5 1870
Type 2: 0.9mm Conductor, 1.8mm Insulated Wire, Copper Wire Screened, RF 0.45 Steel tape thickness 0.5mm
TP816AJ-2YDYbY-S Lg (23/2B0.5)-7Q09 7 1.7/1.8 28.5 1410
TP816AJ-2YDYbY-S Lg (25/2B0.5)-10Q09 10 1.8/2.0 33.0 1745
TP816AJ-2YDYbY-S Lg (25/2B0.5)-14Q09 14 1.8/2.0 36.6 2060
Type 3: 0.9mm Conductor, 1.8mm Insulated Wire, Copper Tape Screened, RF 0.45 Steel tape thickness 0.8mm
TP816AJ-2Y(St)YbY-S Lg (fK) (2B0.8)-20Q09 20 1.8/2.0 40.0 2610
TP816AJ-2Y(St)YbY-S Lg (fK) (2B0.8)-30Q09 30 2.0/2.2 46.5 3425
TP816AJ-2Y(St)YbY-S Lg (fK) (2B0.8)-40Q09 40 2.0/2.2 50.5 4015
Type 4: 0.9mm Conductor, 1.8mm Insulated Wire, Copper Wire Screened, RF 0.25 Steel tape thickness 0.8mm
TP816AJ-2YDYbY-S Lg (29/2B0.8)-20Q09 20 1.8/2.0 40.5 2840
TP816AJ-2YDYbY-S Lg (33/2B0.8)-30Q09 30 2.0/2.2 47.5 3655
TP816AJ-2YDYbY-S Lg (33/2B0.8)-40Q09 40 2.0/2.2 51.5 4230
Type 5: 1.4mm Conductor, 2.7mm Insulated Wire, Copper Tape Screened, RF 0.6 Steel tape thickness 0.5mm
TP816AJ-2Y(St)YbY-S Lg (fK) (2B0.5)-3Q14 3 1.7/1.8 26.5 1140
TP816AJ-2Y(St)YbY-S Lg (fK) (2B0.5)-5Q14 5 1.7/1.8 29.5 1430
TP816AJ-2Y(St)YbY-S Lg (fK) (2B0.5)-7Q14 7 1.8/2.0 33.5 1790
TP816AJ-2Y(St)YbY-S Lg (fK) (2B0.5)-10Q14 10 1.8/2.0 39.0 2330
TP816AJ-2Y(St)YbY-S Lg (fK) (2B0.5)-14Q14 14 1.8/2.0 42.5 2805
Type 6: 1.4mm Conductor, 2.7mm Insulated Wire, Copper Wire Screened, RF 0.45 Steel tape thickness 0.5mm
TP816AJ-2YDYbY-S Lg (25/2B0.5)-25Q14 25 1.8/2.0 35.0 2050
Type 7: 1.4mm Conductor, 2.7mm Insulated Wire, Copper Tape Screened, RF 0.45 Steel tape thickness 0.8mm
TP816AJ-2Y(St)YbY-S Lg (fK) (2B0.8)-20Q14 20 2.0/2.2 49.0 4085
TP816AJ-2Y(St)YbY-S Lg (fK) (2B0.8)-30Q14 30 2.4/2.6 58.5 5585
TP816AJ-2Y(St)YbY-S Lg (fK) (2B0.8)-40Q14 40 2.4/2.6 64.0 6720
Type 8: 1.4mm Conductor, 2.7mm Insulated Wire, Copper Wire Screened, RF 0.25 Steel tape thickness 0.8mm
TP816AJ-2YDYbY-S Lg (29/2B0.5)-10Q14 10 1.8/2.0 41.0 2950
TP816AJ-2YDYbY-S Lg (33/2B0.5)-14Q14 14 2.0/2.2 46.0 3615
TP816AJ-2YDYbY-S Lg (33/2B0.5)-20Q14 20 2.0/2.2 50.0 4310
TP816AJ-2YDYbY-S Lg (38/2B0.5)-30Q14 30 2.4/2.6 59.5 5850
TP816AJ-2YDYbY-S Lg (43/2B0.5)-40Q14 40 2.4/2.6 65.0 7005
 
   
 